• <th id="abimu"></th>

      1. 產(chǎn)品中心

        小鼠骨橋素(OPN)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK1048
        規(guī)格: 價(jià)格:
        48T ¥1680.00
        96T ¥2400.00

        Overview

        Product name: Mouse OPN(Osteopontin) ELISA Kit
        Reactivity: Mouse
        Alternative Names: SPP1; BNSP; BSPI; ETA1; Secreted Phosphoprotein 1; Bone Sialoprotein I; Early T-Lymphocyte Activation 1; Nephropontin; Urinary stone protein; Uropontin
        Assay Type: Sandwich
        Sensitivity: 15 pg/mL
        Standard: 2500 pg/mL
        Detection Range: 39.07-2500 pg/mL
        Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 3.5h
        Research Area: Tumor immunity;Bone metabolism;
        Uniprot ID: P10923
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse OPN. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse OPN. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse OPN, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse OPN in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        2500.00 1.933 1.791
        1250.00 1.573 1.431
        625.00 1.275 1.133
        312.50 0.923 0.781
        156.25 0.601 0.459
        78.13 0.340 0.198
        39.07 0.244 0.102
        0.00 0.142 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant OPN and the recovery rates were calculated by comparing the measured value to the expected amount of OPN in samples.
        Matrix Recovery range Average
        serum(n=5) 78-90% 84%
        EDTA plasma(n=5) 85-97% 91%
        Heparin plasma(n=5) 82-96% 89%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of OPN and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 85-92% 90-96% 79-102% 83-99%
        EDTA plasma(n=5) 88-101% 86-92% 83-98% 96-103%
        Heparin plasma(n=5) 85-94% 87-103% 81-95% 82-90%